ZTE POD1 Specification¶
Introduction¶
POD1(means ZTE-POD1) uses Fuel as the installer and performs os-odl_l2-nofeature-ha CI latest verification. Currently, test projects such as Yardstick, Functest are performing daily CI tasks. Fueature projects such as Doctor, Parser will perform daily and verify CI tasks.
Additional Requirements¶
Server Specifications¶
Jump Host
POD1 share the same Jump Host in the lab.
Deploy server
Hostname | Vendor | Model | Serial Number | CPUs | Memory (GB) | Local Storage | 1GbE: NIC#/IP MAC/VLAN/Network | 10GbE: NIC#/IP MAC/VLAN/Network | Notes |
Jellyfish | ZTE | R5300 | 277662500093 | E5-2620x2 | 128 | 600GB SAS 4 TB HDD | IF0: 74:4a:a4:00:91:b3/ 10.20.6.1/ native vlan/PXE IF1: 74:4a:a4:00:91:b4/ 10.20.7.1/ native vlan/PXE |
Nodes/Servers
Hostname | Vendor | Model | Serial Number | CPUs | Memory (GB) | Local Storage | Lights-out network (IPMI): IP/MAC, U/P | 1GbE: NIC#/IP MAC/VLAN/Network | 10GbE: NIC#/IP MAC/VLAN/Network | Notes |
node1 | ZTE | E9000 | 281498500141 | E5-2680x2 | 128 | 600GB HDD | 129.5.1.101 4c:09:b4:b2:59:84 zteroot/superuser | enp129s0f0: 4c:09:b4:b2:59:87 vlan 1/PXE vlan 101/management | enp2s0f0: 4c:09:b4:b1:de:38 vlan 1/ public vlan 103/ private enp132s0f0: 4c:09:b4:b1:de:3a vlan 102/ storage | |
node2 | ZTE | E9000 | 281498500179 | E5-2680x2 | 128 | 600GB HDD | 129.5.1.22 4c:09:b4:b2:59:f9 zteroot/superuser | enp129s0f0: 4c:09:b4:b2:59:fc vlan 1/PXE vlan 101/management | enp2s0f0: 4c:09:b4:b1:de:40 vlan 1/ public vlan 103/ private enp132s0f0: 4c:09:b4:b1:de:42 vlan 102/ storage | |
node3 | ZTE | E9000 | 281498500008 | E5-2680x2 | 128 | 600GB HDD | 129.5.1.3 4c:09:b4:b2:59:9f zteroot/superuser | enp129s0f0: 4c:09:b4:b2:59:a2 vlan 1/PXE vlan 101/management | enp2s0f0: 4c:09:b4:b1:de:1c vlan 1/ public vlan 103/ private enp132s0f0: 4c:09:b4:b1:de:1e vlan 102/ storage | |
node4 | ZTE | E9000 | 281498500157 | E5-2680x2 | 128 | 600GB HDD | 129.5.1.4 4c:09:b4:b2:59:d5 zteroot/superuser | enp129s0f0: 4c:09:b4:b2:59:d8 vlan 1/PXE vlan 101/management | enp2s0f0: 4c:09:b4:b1:de:18 vlan 1/ public vlan 103/ private enp132s0f0: 4c:09:b4:b1:de:1a vlan 102/ storage | |
node5 | ZTE | E9000 | 281498500119 | E5-2680x2 | 128 | 600GB HDD | 129.5.1.5 4c:09:b4:b2:59:72 zteroot/superuser | enp129s0f0: 4c:09:b4:b2:59:75 vlan 1/PXE vlan 101/management | enp2s0f0: 4c:09:b4:b1:de:48 vlan 1/ public vlan 103/ private enp132s0f0: 4c:09:b4:b1:de:4a vlan 102/ storage |
Subnet allocations
Network name | Address | Mask | Gateway | VLAN id |
Public | 172.10.0.0 | 255.255.255.0 | 172.10.0.1 | untagged |
Fuel Admin/PXE | 10.20.0.0 | 255.255.255.0 | 10.20.0.2 | native vlan 1 |
Fuel Mangement | 192.168.10.0 | 255.255.255.0 | 101 | |
Fuel Storage | 192.168.11.0 | 255.255.255.0 | 102 |
VPN Users¶
Name | Project | Role | Notes | |
Firewall Rules¶
Port(s) | Service | Note |
1194(OpenVPN) | Jenkins |