ZTE POD2 Specification

Introduction

POD2(means ZTE-POD2) uses Fuel as the installer and performs os-odl_l2-nofeature-ha CI latest verification. Qtip daily CI task will be migrated from POD1 to POD2. Qtip is also working on integration with Yardstick umbrella project.

Additional Requirements

Server Specifications

Jump Host

POD2 share the same Jump Host in the lab.

Deploy Server

POD2 share the same Deploy Server with POD1.

Hostname Vendor Model Serial Number CPUs Memory (GB) Local Storage 1GbE: NIC#/IP MAC/VLAN/Network 10GbE: NIC#/IP MAC/VLAN/Network Notes
Jellyfish ZTE R5300 277662500093 E5-2620x2 128 600GB SAS 4 TB HDD IF0: 74:4a:a4:00:91:b3/ 10.20.6.1/ native vlan/PXE IF1: 74:4a:a4:00:91:b4/ 10.20.7.1/ native vlan/PXE    

Nodes/Servers

Hostname Vendor Model Serial Number CPUs Memory (GB) Local Storage Lights-out network (IPMI): IP/MAC, U/P 1GbE: NIC#/IP MAC/VLAN/Network 10GbE: NIC#/IP MAC/VLAN/Network Notes
node1 ZTE E9000 701763100114 E5-2650x2 128 600GB*2 HDD 192.168.1.106 74:4a:a4:00:cd:6f zteroot/superuser ens4f0: 74:4a:a4:00:cd:72 native vlan 170/PXE ens12f0: 74:4a:a4:00:b0:e9 vlan 171/ management ens12f1: 74:4a:a4:00:b0:ea vlan 172/ storage ens44f0: 74:4a:a4:00:b0:eb vlan 1130/ private ens44f1: 74:4a:a4:00:b0:ec vlan 173/ public  
node2 ZTE E9000 701360500105 E5-2650x2 128 600GB*2 HDD 192.168.1.107 74:4a:a4:00:ca:c9 zteroot/superuser ens4f0: 74:4a:a4:00:ca:cc native vlan 170/PXE ens12f0: 74:4a:a4:00:d6:a3 vlan 171/ management ens12f1: 74:4a:a4:00:d6:a4 vlan 172/ storage ens44f0: 74:4a:a4:00:d6:99 vlan 1130/ private ens44f1: 74:4a:a4:00:d6:9a vlan 173/ public  
node3 ZTE E9000 701360500026 E5-2650x2 128 600GB*2 HDD 192.168.1.108 74:4a:a4:00:cd:0f zteroot/superuser ens4f0: 74:4a:a4:00:cd:12 native vlan 170/PXE ens12f0: 74:4a:a4:00:d6:9d vlan 171/ management ens12f1: 74:4a:a4:00:d6:9e vlan 172/ storage ens44f0: 74:4a:a4:00:d3:15 vlan 1130/ private ens44f1: 74:4a:a4:00:d3:16 vlan 173/ public  
node4 ZTE E9000 701763100099 E5-2650x2 128 600GB*2 HDD 192.168.1.109 74:4a:a4:00:cf:3d zteroot/superuser ens4f0: 74:4a:a4:00:cf:40 native vlan 170/PXE ens12f0: 74:4a:a4:00:d6:a5 vlan 171/ management ens12f1: 74:4a:a4:00:d6:a6 vlan 172/ storage ens44f0: 74:4a:a4:00:d6:a7 vlan 1130/ private ens44f1: 74:4a:a4:00:d6:a8 vlan 173/ public  
node5 ZTE E9000 701763100018 E5-2650x2 128 600GB*2 HDD 192.168.1.110 74:4a:a4:00:ce:d1 zteroot/superuser ens4f0: 74:4a:a4:00:ce:d4 native vlan 170/PXE ens12f0: 74:4a:a4:00:d2:c3 vlan 171/ management ens12f1: 74:4a:a4:00:d2:c4 vlan 172/ storage ens44f0: 74:4a:a4:00:d2:c1 vlan 1130/ private ens44f1: 74:4a:a4:00:d2:c2 vlan 173/ public  

Subnet allocations

Network name Address Mask Gateway VLAN id
Public 172.70.0.0 255.255.255.0 172.70.0.1 173
Fuel Admin 10.20.7.0 255.255.255.0 10.20.7.1 native vlan 170
Fuel Mangement 192.168.71.0 255.255.255.0   171
Fuel Storage 192.168.72.0 255.255.255.0   172

VPN Users

Name Email Project Role Notes
         

Firewall Rules

Port(s) Service Note
1194(OpenVPN) Jenkins  

POD Topology

POD diagram not found