.. This work is licensed under a Creative Commons Attribution 4.0 International License. .. http://creativecommons.org/licenses/by/4.0 Annex: NFVI Faults ================================================= Faults in the listed elements need to be immediately notified to the Consumer in order to perform an immediate action like live migration or switch to a hot standby entity. In addition, the Administrator of the host should trigger a maintenance action to, e.g., reboot the server or replace a defective hardware element. Faults can be of different severity, i.e., critical, warning, or info. Critical faults require immediate action as a severe degradation of the system has happened or is expected. Warnings indicate that the system performance is going down: related actions include closer (e.g. more frequent) monitoring of that part of the system or preparation for a cold migration to a backup VM. Info messages do not require any action. We also consider a type "maintenance", which is no real fault, but may trigger maintenance actions like a re-boot of the server or replacement of a faulty, but redundant HW. Faults can be gathered by, e.g., enabling SNMP and installing some open source tools to catch and poll SNMP. When using for example Zabbix one can also put an agent running on the hosts to catch any other fault. In any case of failure, the Administrator should be notified. The following tables provide a list of high level faults that are considered within the scope of the Doctor project requiring immediate action by the Consumer. **Compute/Storage** +-------------------+----------+------------+-----------------+------------------+ | Fault | Severity | How to | Comment | Immediate action | | | | detect? | | to recover | +===================+==========+============+=================+==================+ | Processor/CPU | Critical | Zabbix | | Switch to hot | | failure, CPU | | | | standby | | condition not ok | | | | | +-------------------+----------+------------+-----------------+------------------+ | Memory failure/ | Critical | Zabbix | | Switch to | | Memory condition | | (IPMI) | | hot standby | | not ok | | | | | +-------------------+----------+------------+-----------------+------------------+ | Network card | Critical | Zabbix/ | | Switch to | | failure, e.g. | | Ceilometer | | hot standby | | network adapter | | | | | | connectivity lost | | | | | +-------------------+----------+------------+-----------------+------------------+ | Disk crash | Info | RAID | Network storage | Inform OAM | | | | monitoring | is very | | | | | | redundant (e.g. | | | | | | RAID system) | | | | | | and can | | | | | | guarantee high | | | | | | availability | | +-------------------+----------+------------+-----------------+------------------+ | Storage | Critical | Zabbix | | Live migration | | controller | | (IPMI) | | if storage | | | | | | is still | | | | | | accessible; | | | | | | otherwise hot | | | | | | standby | +-------------------+----------+------------+-----------------+------------------+ | PDU/power | Critical | Zabbix/ | | Switch to | | failure, power | | Ceilometer | | hot standby | | off, server reset | | | | | +-------------------+----------+------------+-----------------+------------------+ | Power | Warning | SNMP | | Live migration | | degration, power | | | | | | redundancy lost, | | | | | | power threshold | | | | | | exceeded | | | | | +-------------------+----------+------------+-----------------+------------------+ | Chassis problem | Warning | SNMP | | Live migration | | (e.g. fan | | | | | | degraded/failed, | | | | | | chassis power | | | | | | degraded), CPU | | | | | | fan problem, | | | | | | temperature/ | | | | | | thermal condition | | | | | | not ok | | | | | +-------------------+----------+------------+-----------------+------------------+ | Mainboard failure | Critical | Zabbix | e.g. PCIe, SAS | Switch to | | | | (IPMI) | link failure | hot standby | +-------------------+----------+------------+-----------------+------------------+ | OS crash (e.g. | Critical | Zabbix | | Switch to | | kernel panic) | | | | hot standby | +-------------------+----------+------------+-----------------+------------------+ **Hypervisor** +----------------+----------+------------+-------------+-------------------+ | Fault | Severity | How to | Comment | Immediate action | | | | detect? | | to recover | +================+==========+============+=============+===================+ | System has | Critical | Zabbix | | Switch to | | restarted | | | | hot standby | +----------------+----------+------------+-------------+-------------------+ | Hypervisor | Warning/ | Zabbix/ | | Evacuation/switch | | failure | Critical | Ceilometer | | to hot standby | +----------------+----------+------------+-------------+-------------------+ | Hypervisor | Warning | Alarming | Zabbix/ | Rebuild VM | | status not | | service | Ceilometer | | | retrievable | | | unreachable | | | after certain | | | | | | period | | | | | +----------------+----------+------------+-------------+-------------------+ **Network** +------------------+----------+---------+----------------+---------------------+ | Fault | Severity | How to | Comment | Immediate action to | | | | detect? | | recover | +==================+==========+=========+================+=====================+ | SDN/OpenFlow | Critical | Ceilo- | | Switch to | | switch, | | meter | | hot standby | | controller | | | | or reconfigure | | degraded/failed | | | | virtual network | | | | | | topology | +------------------+----------+---------+----------------+---------------------+ | Hardware failure | Warning | SNMP | Redundancy of | Live migration if | | of physical | | | physical | possible otherwise | | switch/router | | | infrastructure | evacuation | | | | | is reduced or | | | | | | no longer | | | | | | available | | +------------------+----------+---------+----------------+---------------------+ .. Revision: 34fa08e7f2bf2452659eb6c306c325f282cbb3ec Build date: 2016-09-08